189 research outputs found

    Comparison of artifacts between paste and collodion method of electrode application in pediatric EEG

    Get PDF
    © 2019 International Federation of Clinical Neurophysiology Objectives: Children pose challenges to obtain quality EEG data due to excessive artifact. Collodion is used in EEG electrodes due to its water resistance and strong adhesive qualities. This study was done to evaluate differences in artifacts between the collodion and paste method. Methods: 115 subjects (children age \u3e3 years) were randomized into paste and collodion groups and artifacts evaluated at baseline and every hour over 30 s increments. Age, sleep state, and number of electrodes with artifact were also documented. T-test was performed to determine differences in the various parameters between the two groups. Results: 61 subjects were in the paste group and 54 in the collodion group. Mean of total seconds of artifact from 0 to 24 h were 41.8 s in paste group versus 30.3 s in collodion group (P = 0.02). Children \u3e11 years old had less artifact than younger children from 0 to 24 h (24.3 versus 41.2 s, P = 0.03), and from 24 to 48 h (33.1 versus 43.1 s, P = 0.03). There was a significant effect of sleep vs. awake state recordings on artifact from 0 to 24 h (30.3 versus 50.2 s, P = 0.01). Conclusion: Electrode problems are common with both collodion and paste in prolonged AEEG monitoring. However, for studies less than 24 h, collodion may be a better alternative. Significance: Our study provides evidence that in some cases collodion may be a better alternative to paste in terms of decreased artifacts

    Comparison of artifacts between paste and collodion method of electrode application in pediatric EEG

    Get PDF
    Objectives: Children pose challenges to obtain quality EEG data due to excessive artifact. Collodion is used in EEG electrodes due to its water resistance and strong adhesive qualities. This study was done to evaluate differences in artifacts between the collodion and paste method. Methods: 115 subjects (children age \u3e 3 years) were randomized into paste and collodion groups and artifacts evaluated at baseline and every hour over 30s increments. Age, sleep state, and number of electrodes with artifact were also documented. T-test was performed to determine differences in the various parameters between the two groups. Results: 61 subjects were in the paste group and 54 in the collodion group. Mean of total seconds of artifact from 0 to 24h were 41.8s in paste group versus 30.3s in collodion group (P=0.02). Children \u3e 11 years old had less artifact than younger children from 0 to 24h (24.3 versus 41.2s, P=0.03), and from 24 to 48h (33.1 versus 43.1s, P=0.03). There was a significant effect of sleep vs. awake state recordings on artifact from 0 to 24h (30.3 versus 50.2s, P=0.01). Conclusion: Electrode problems are common with both collodion and paste in prolonged AEEG monitoring. However, for studies less than 24h, collodion may be a better alternative. Significance: Our study provides evidence that in some cases collodion may be a better alternative to paste in terms of decreased artifacts

    BICEP3: a 95 GHz refracting telescope for degree-scale CMB polarization

    Full text link
    BICEP3 is a 550 mm-aperture refracting telescope for polarimetry of radiation in the cosmic microwave background at 95 GHz. It adopts the methodology of BICEP1, BICEP2 and the Keck Array experiments - it possesses sufficient resolution to search for signatures of the inflation-induced cosmic gravitational-wave background while utilizing a compact design for ease of construction and to facilitate the characterization and mitigation of systematics. However, BICEP3 represents a significant breakthrough in per-receiver sensitivity, with a focal plane area 5×\times larger than a BICEP2/Keck Array receiver and faster optics (f/1.6f/1.6 vs. f/2.4f/2.4). Large-aperture infrared-reflective metal-mesh filters and infrared-absorptive cold alumina filters and lenses were developed and implemented for its optics. The camera consists of 1280 dual-polarization pixels; each is a pair of orthogonal antenna arrays coupled to transition-edge sensor bolometers and read out by multiplexed SQUIDs. Upon deployment at the South Pole during the 2014-15 season, BICEP3 will have survey speed comparable to Keck Array 150 GHz (2013), and will significantly enhance spectral separation of primordial B-mode power from that of possible galactic dust contamination in the BICEP2 observation patch.Comment: 12 pages, 5 figures. Presented at SPIE Astronomical Telescopes and Instrumentation 2014: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII. To be published in Proceedings of SPIE Volume 915

    Keck array and BICEP3: spectral characterization of 5000+ detectors

    Get PDF
    The inflationary paradigm of the early universe predicts a stochastic background of gravitational waves which would generate a B-mode polarization pattern in the cosmic microwave background (CMB) at degree angular scales. Precise measurement of B-modes is one of the most compelling observational goals in modern cosmology. Since 2011, the Keck Array has deployed over 2500 transition edge sensor (TES) bolometer detectors at 100 and 150 GHz to the South Pole in pursuit of degree-scale B-modes, and Bicep3 will follow in 2015 with 2500 more at 100 GHz. Characterizing the spectral response of these detectors is important for controlling systematic effects that could lead to leakage from the temperature to polarization signal, and for understanding potential coupling to atmospheric and astrophysical emission lines. We present complete spectral characterization of the Keck Array detectors, made with a Martin-Puplett Fourier Transform Spectrometer at the South Pole, and preliminary spectra of Bicep3 detectors taken in lab. We show band centers and effective bandwidths for both Keck Array bands, and use models of the atmosphere at the South Pole to cross check our absolute calibration. Our procedure for obtaining interferograms in the field with automated 4-axis coupling to the focal plane represents an important step towards efficient and complete spectral characterization of next-generation instruments more than 10000 detectors

    Optical characterization of the BICEP3 CMB polarimeter at the South Pole

    Get PDF
    BICEP3 is a small-aperture refracting cosmic microwave background (CMB) telescope designed to make sensitive polarization maps in pursuit of a potential B-mode signal from inflationary gravitational waves. It is the latest in the Bicep/Keck Array series of CMB experiments located at the South Pole, which has provided the most stringent constraints on inflation to date. For the 2016 observing season, BICEP3 was outfitted with a full suite of 2400 optically coupled detectors operating at 95 GHz. In these proceedings we report on the far field beam performance using calibration data taken during the 2015-2016 summer deployment season in situ with a thermal chopped source. We generate high-fidelity per-detector beam maps, show the array-averaged beam profile, and characterize the differential beam response between co-located, orthogonally polarized detectors which contributes to the leading instrumental systematic in pair differencing experiments. We find that the levels of differential pointing, beamwidth, and ellipticity are similar to or lower than those measured for Bicep2 and Keck Array. The magnitude and distribution of Bicep3’s differential beam mismatch – and the level to which temperature-to-polarization leakage may be marginalized over or subtracted in analysis - will inform the design of next-generation CMB experiments with many thousands of detectors

    BICEP2 II: Experiment and Three-Year Data Set

    Full text link
    We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1 to 5 degrees (ℓ\ell=40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26~cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μ\muK sqrt(s). The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.2 μ\muK arcmin) over an effective area of 384 square degrees within a 1000 square degree field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.Comment: 30 pages, 24 figure

    BICEP2 / Keck Array V: Measurements of B-mode Polarization at Degree Angular Scales and 150 GHz by the Keck Array

    Full text link
    The Keck Array is a system of cosmic microwave background (CMB) polarimeters, each similar to the BICEP2 experiment. In this paper we report results from the 2012 and 2013 observing seasons, during which the Keck Array consisted of five receivers all operating in the same (150 GHz) frequency band and observing field as BICEP2. We again find an excess of B-mode power over the lensed-Λ\LambdaCDM expectation of >5σ> 5 \sigma in the range 30<ℓ<15030 < \ell < 150 and confirm that this is not due to systematics using jackknife tests and simulations based on detailed calibration measurements. In map difference and spectral difference tests these new data are shown to be consistent with BICEP2. Finally, we combine the maps from the two experiments to produce final Q and U maps which have a depth of 57 nK deg (3.4 μ\muK arcmin) over an effective area of 400 deg2^2 for an equivalent survey weight of 250,000 μ\muK−2^{-2}. The final BB band powers have noise uncertainty a factor of 2.3 times better than the previous results, and a significance of detection of excess power of >6σ> 6\sigma.Comment: 13 pages, 9 figure

    BICEP2 / Keck Array VIII: Measurement of gravitational lensing from large-scale B-mode polarization

    Get PDF
    We present measurements of polarization lensing using the 150 GHz maps which include all data taken by the BICEP2 & Keck Array CMB polarization experiments up to and including the 2014 observing season (BK14). Despite their modest angular resolution (∼0.5∘\sim 0.5^\circ), the excellent sensitivity (∼3μ\sim 3\muK-arcmin) of these maps makes it possible to directly reconstruct the lensing potential using only information at larger angular scales (ℓ≤700\ell\leq 700). From the auto-spectrum of the reconstructed potential we measure an amplitude of the spectrum to be ALϕϕ=1.15±0.36A^{\phi\phi}_{\rm L}=1.15\pm 0.36 (Planck Λ\LambdaCDM prediction corresponds to ALϕϕ=1A^{\phi\phi}_{\rm L}=1), and reject the no-lensing hypothesis at 5.8σ\sigma, which is the highest significance achieved to date using an EB lensing estimator. Taking the cross-spectrum of the reconstructed potential with the Planck 2015 lensing map yields ALϕϕ=1.13±0.20A^{\phi\phi}_{\rm L}=1.13\pm 0.20. These direct measurements of ALϕϕA^{\phi\phi}_{\rm L} are consistent with the Λ\LambdaCDM cosmology, and with that derived from the previously reported BK14 B-mode auto-spectrum (ALBB=1.20±0.17A^{\rm BB}_{\rm L}=1.20\pm 0.17). We perform a series of null tests and consistency checks to show that these results are robust against systematics and are insensitive to analysis choices. These results unambiguously demonstrate that the B-modes previously reported by BICEP / Keck at intermediate angular scales (150≲ℓ≲350150\lesssim\ell\lesssim 350) are dominated by gravitational lensing. The good agreement between the lensing amplitudes obtained from the lensing reconstruction and B-mode spectrum starts to place constraints on any alternative cosmological sources of B-modes at these angular scales.Comment: 12 pages, 8 figure
    • …
    corecore